This coverage includes all identified petroleum program contaminated discharge sites where cleanup is ongoing or complete. Discharge cleanup sites may be eligible or ineligible for state funding assistance. More than one discharge site may be present at a current or former petroleum storage tank facility.
This layer displays the location and cleanup status for cleanup sites contaminated by discharges of petroleum and petroleum products from stationary petroleum storage systems. These discharge sites include those determined eligible for state funded cleanup (aka eligible discharges) as well as non-program or voluntary cleanup sites (aka ineligible discharges) that are funded by responsible parties.This new layer replaces the Petroleum Contamination Monitoring (PCTS) from STCM layer.
publication date
Because a variety of sources and methods were used to derive information for this data, the quality of the locations may vary accordingly.The data is undergoing review to improve accuracy. This data is intended to be used for general locational representation and should not be considered appropriate for legal and/or cadastral purposes. The locational data point of each is provided by the responsible party and reviewed by the Florida Department of Environmental Protection (FDEP) agency staff. FDEP makes no representations of any kind, including, but not limited to, the warranties of merchantability or fitness for a particular use, nor are any such warranties to be implied with respect to the digital data layers furnished hereunder. FDEP assumes no responsibility to maintain them in any manner or form. By using data provided herein, the user acknowledges that terms and conditions have been read and that the user is bound by these criteria.
2600 Blair Stone Rd
FDEP,DWM
GeoPlan relied on the integrity of the attribute information within the original data.
This data is provided 'as is'. GeoPlan relied on the integrity of the original data layer's topology
This data is provided 'as is' by GeoPlan and is complete to our knowledge.
This data is provided 'as is' and its horizontal positional accuracy has not been verified by GeoPlan
This data is provided 'as is' and its vertical positional accuracy has not been verified by GeoPlan
Spatial and Attribute Information
Inception of the GIS layer refresh process based on a SQL query provided by Lissie Bartlett (DWM). Data in SDE is refreshed nightly from the program area Oracle production databases. This new layer replaces the Petroleum Contamination Monitoring (PCTS) from STCM layer in DataMiner and MapDirect.
2600 Blair Stone Rd MS 6520
This dataset was downloaded by the GeoPlan Center on 1/2/2019 from the FDEP website (http://geodata.dep.state.fl.us/). The data was received as a geodatabase and was in the following projection: NAD_1983_HARN_Florida_GDL_Albers. This dataset is updated daily. Contact the FDEP for the most recent data. The dataset has a number of points located outside the boundaries of Florida and in bodies of water. As these points are reviewed they should be corrected by FDEP over time. The source layer from FDEP changed as of 1/4/2016 for the layer pcts. Previously based on pcts_sp, this layer is now received as pcts_discharges_sp. Changes inlcude field names and table structure. - Added the field DESCRIPT based on FACILITY_N. - Added fields LAT_DD_1, LONG_DD_1, MGRS, and GOOGLEMAP. LAT_DD_1 and LONG_DD_1 were calculated using the calculate geometry command and selecting decimal degrees as the units. MGRS was calculated using the Convert Coordinate Notation tool and selecting Output coordinate Format as MGRS. The GOOGLEMAP field was calculated by concatenating: "https://www.google.com/maps/place/" & [MGRS]. - Added the field FGDLAQDATE based on date downloaded from source. - Upcased all text in the attribute table except for DOCUMENTS field. - Data set was renamed pcts_jan19 from PCTS_DISCHARGES_SP
Dataset copied.
Internal feature number.
ESRI
Feature geometry.
ESRI
Unique ID assigned to a Facility
FDEP
County
FDEP
Facility name
FDEP
Unique ID assigned to a discharge.
STCM Database tables
The date of discharge as reported by the responsible party; there cannot be more than one discharge per day per facility.
STCM Database tables
Score given to a facility after the well survey. The score is determined by several criteria developed by the Petroleum Restoration Program (PRP), such as proximity to potable water systems, homes, etc. The valid range of scores is between 1 and 100. The higher the score, the worse the spill
STCM Database tables
Is the Facility eligible for funding.
STCM Database tables
Facility eligible for funding
Facility ineligible for funding
Short name code for current eligibility program for the discharge based on a determination of E, P or A and max letter of determination date
STCM Database tables
Abandoned Tank Restoration Program
Statutory Discrection / Bco Approved
Early Detection Incentive
Good Samaritan
Hardship Case
Innocent Victim Petroleum Storage System Restoration Program
Final Judgement
Lust Trust Fund
Non-Program/3rd Party Defense
Non-Program/Consent Order
Non-Program/Unknown Responsible Party
Petroleum Cleanup Participation Program
Petroleum Liability And Restoration Insurance Program
Settlement Agreement
Site Rehabilitation Funding Agreement
General cleanup status
STCM Database tables
This facility is in closure
This facility is eligible for cleanup
This facility will not need any cleanup
This facility has reported a discharge
This facility is currently undergoing cleanup
The discharges current cleanup status.
STCM Database tables
Approved - No Task Level Data
Denied Cleanup Assistance
Discharge Notification Received
Eligible - No Task Level Data
Ineligible For Cleanup Assistance
Low Score Site Initiative No Further Action - Minimal Contamination Remains Onsite
No Further Action Status Has Been Approved
No Further Action With Conditions
Cleanup Not Required - Cleanup Is Not Required By Chapter 17-770 Rules
Partial Eligibility - No Task Level Data
Ra Ongoing - Remedial Action Cleanup Activity In Progress
Rap Ongoing - Remedial Action Plan Cleanup Activity In Progress
Report Of Discharge Received
Remediation By Natural Attenuation
Sa Ongoing - Site Assessment Cleanup Activity In Progress
Sr Ongoing - Source Removal Cleanup Task In Progress
Srcr Complete - Site Rehabilitation Completion Report Has Been Approved
Verified Contamination, Cleanup Required
Discharge cleanup status effective date
STCM Database tables
(Phase) associated to the last report received that has a subtask ID (Subphase)
STCM Database tables
Performance-Based Cleanup - None
Remedial Action
Remedial Action Plan
Site Assessment
Source Removal
Subtask ID (Subphase) based on last report received that has a subtask ID were status of report is not W, U or R
STCM Database tables
Low Scored Site Initiative
Natural Attenuation Monitoring
Operation And Maintenance
Post Remedial Action Monitoring Plan
Remedial Action Construction
Remedial Action Plan
Site Assessment
Source Removal
Well Abandonment Site Closure
Received Date associated to the Report Subphase
STCM Database tables
Office in which the site management of the discharge has been assigned (Local Program, District or Tallahassee)
STCM Database tables
Staff member assigned to the facility discharge
STCM Database tables
Street address or physical location by direction
STCM Database tables
City the facility is located in.
STCM Database tables
Zip code of the county
STCM Database tables
Type of facility
STCM Database tables
Facility status
STCM Database tables
Latitude - Degrees Location Identifier
STCM Database tables
Latitude - Minutes Location Identifier
STCM Database tables
Latitude - Seconds Location Identifier
STCM Database tables
Longitude - Degrees Location Identifier
STCM Database tables
Longitude - Minutes Location Identifier
STCM Database tables
Longitude - Seconds Location Identifier
STCM Database tables
Datum associated with the location of the facility.
STCM Database tables
High Precision GIS Network / High Precision Geodetic Reference
FDEP
World Geodetic Survey of 1984
FDEP
North American Datum of 1927
FDEP
North American Datum of 1983
FDEP
This is the relative feature to the point location to the facility
STCM Database tables
Administrative Center of Site or Facility containing Feature Location
Approximate Feature Location
Center of Site or Facility containing Feature Location
Entrance to Site or Facility containg Feature Location
Exact Feature Location
Offset to Exact Feature Location
A prominent object located within the Site or Facility
Vicinity of Feature Location
The method used to collect the locational information.
STCM Database tables
Address Matching
Autonomous GPS
Differentially Corrected GPS
Digital Map Interpolation
Digital Aerial Photography with Ground Control
Geodetic Quality Global Positioning System (GPS)
Manual Map Interpolation
Unverified
GPS with Wide-Area Augmentation Service Correction
Name of the staff who collected locational informtion.
STCM Database tables
Date locational information was collected
STCM Database tables
Link to the facility documents.
STCM Database tables
Latitude in decimal degrees.
Esri
Longitude in decimal degrees.
Esri
Military Grid Reference System (MGRS) Coordinate of the Facility. The MGRS is the geocoordinate standard used by NATO militaries for locating points on the earth. The MGRS provides a means to represent any location on the surface of the Earth using an alphanumeric string. Hierarchical references are based on the Universal Transverse Mercator (UTM) coordinate system. The MGRS is used for the entire earth. http://mgrs-data.org/
GeoPlan
Webpage hyperlink to location in Google Maps.
GeoPlan
FGDL added field based on FACILITY_N
GeoPlan
FGDL added field based on date downloaded from source
GeoPlan
Unique ID added by GeoPlan
GeoPlan
431 Architecture PO Box 115706
The Florida Geographic Data Library is a collection of Geospatial Data compiled by the University of Florida GeoPlan Center with support from the Florida Department of Transportation. GIS data available in FGDL is collected from various state, federal, and other agencies (data sources) who are data stewards, producers, or publishers. The data available in FGDL may not be the most current version of the data offered by the data source. University of Florida GeoPlan Center makes no guarantees about the currentness of the data and suggests that data users check with the data source to see if more recent versions of the data exist. Furthermore, the GIS data available in the FGDL are provided 'as is'. The University of Florida GeoPlan Center makes no warranties, guaranties or representations as to the truth, accuracy or completeness of the data provided by the data sources. The University of Florida GeoPlan Center makes no representations or warranties about the quality or suitability of the materials, either expressly or implied, including but not limited to any implied warranties of merchantability, fitness for a particular purpose, or non-infringement. The University of Florida GeoPlan Center shall not be liable for any damages suffered as a result of using, modifying, contributing or distributing the materials. A note about data scale: Scale is an important factor in data usage. Certain scale datasets are not suitable for some project, analysis, or modeling purposes. Please be sure you are using the best available data. 1:24000 scale datasets are recommended for projects that are at the county level. 1:24000 data should NOT be used for high accuracy base mapping such as property parcel boundaries. 1:100000 scale datasets are recommended for projects that are at the multi-county or regional level. 1:125000 scale datasets are recommended for projects that are at the regional or state level or larger. Vector datasets with no defined scale or accuracy should be considered suspect. Make sure you are familiar with your data before using it for projects or analysis. Every effort has been made to supply the user with data documentation. For additional information, see the References section and the Data Source Contact section of this documentation. For more information regarding scale and accuracy, see our webpage at: http://geoplan.ufl.edu/education.html
2600 Blair Stone Rd MS 6520